Skip to content

Fix for #157 which makes the "Stacking Lip Top Ledge" property of a bin editable - #160

Open
dan-nj wants to merge 1 commit into
Stu142:masterfrom
dan-nj:upper-chamfer-fix-#157
Open

dan-nj wants to merge 1 commit into
Stu142:masterfrom
dan-nj:upper-chamfer-fix-#157

Conversation

@dan-nj

@dan-nj dan-nj commented Aug 14, 2026

Copy link
Copy Markdown

Fix for #157 which makes the "Stacking Lip Top Ledge" property of a bin editable (non-read-only), and moves it to the "Gridfinity Non Standard" section instead of "zz Expert Only".

If the Stacking Lip Top Ledge is then set to 0.0mm as per the Gridfinity specification, as opposed to the 0.4mm default, to give a flattened top to the bin, the top chamfer size automatically adjusts from 1.5mm to 1.9mm to match the Gridfinity specification, and the total height of a 2U stackable bin (for example) becomes 18.4mm instead of 18.0mm.

If the Stacking Lip Top Ledge property is not adjusted, behaviour remains as before.

Also included:

  • A partial update for a similar issue with baseplates is also included to allow adjustment of their top ledges. Further work is required to automatically adjust the size of the top chamfer on a baseplate where the top ledge is altered, for example the chamfer should increase from 1.75mm to 2.15mm if the top ledge is reduced from 0.4mm to 0.0mm.

  • Finally, some refactoring of property section naming has been implemented with constant definitions in const.py to make the code more DRY.

…of a bin editable (non-read-only), and moves it to the "Gridfinity Non Standard" section instead of "zz Expert Only".

If the Stacking Lip Top Ledge is then set to 0.0mm as per the Gridfinity specification, as opposed to the 0.4mm default, to give a flattened top to the bin, the top chamfer size automatically adjusts from 1.5mm to 1.9mm to match the Gridfinity specification, and the total height of a 2U stackable bin (for example) becomes 18.4mm instead of 18.0mm.

If the Stacking Lip Top Ledge property is not adjusted, behaviour remains as before.

A partial update for a similar issue with baseplates is also included to allow adjustment of their top ledges.  Further work is required to automatically adjust the size of the top chamfer on a baseplate where the top ledge is altered, for example the chamfer should increase from 1.75mm to 2.15mm if the top ledge is reduced from 0.4mm to 0.0mm.

Finally, some refactoring of property section naming has been implemented with constant definitions in const.py to make the code more DRY.
@dan-nj

dan-nj commented Oct 24, 2026

Copy link
Copy Markdown
Author

I received a notification in relation to this pull request with the following details:

Tests: No jobs were run

Tests
This workflow run required approval but was not approved before it expired.

Happy to do further work on this PR as necessary to get it merged, if a maintainer is able to review.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant