Skip to content

[Code scan] Water HTI MBAR bond_angle_off uses the wrong branch #126

Open

Description

@njzjz

Source: Codex global repository scan of deepmodeling/dpti at commit b719828.
Project: DeepModeling Agent Code Scan

Problem
The MBAR path in hti_water._post_tasks_mbar() contains if step == 'angle_on' or 'deep_on':, which is always true because the string 'deep_on' is truthy. Therefore the bond_angle_off branch never uses the intended -de * (1-ll) reduced-potential construction, which can silently corrupt MBAR free energies for water HTI.

Code references

if step == 'angle_on' :

if step == 'angle_on' or 'deep_on':

block_u.append(-de * (1-ll))

Reproduction
Unit-test _post_tasks_mbar(..., step='bond_angle_off') with mocked thermo data and inspect the generated block_u. The current code always takes the angle/deep branch instead of the else branch.

Expected result
The condition should explicitly test both positive cases, for example if step in ('angle_on', 'deep_on'), so bond_angle_off uses the intended reduced-potential formula.